DBD22 - DCC Block Detector (Added May 29, 2007)

The DBD22 is a dual block occupancy detector. It provides complete isolation from the track by using small transformer type sensors. This also means there is no drop in track voltage as there is with sensing diodes. The DBD22 is designed to work well with the SIC24 signal and indicator controller.

MSRP - $21.95

Board size: 1.5" X 1.8"

Operation:

The DBD22 is capable of sensing current in two isolated sections of track called blocks. This provides for detecting the presence of locomotives or other rolling stock that draw current from the track.

The track feeder wire for one rail of the block is passed through the hole in the sensor (see diagram below) before connecting the feeder to the track. When the current in the feeder going though the sensor reaches the trigger level, the output is turned on and the LED lights showing the block is occupied. Passing the feeder though the sensor more than one time will increased the sensitivity. However, this is NOT recommended because the maximum sensor current specification will be greatly reduced.

Locomotives and lighted cars draw enough current to trigger the DBD22. In order for other rolling stock to draw current, resistive wheel sets will have to be added. For HO scale, one 4.7K ohm resistive wheel set will work per car.  If you want to use 10K resistive wheel sets you will need two wheel sets per car.

Duty track can cause intermittent current flow. A built in filter keeps the DBD22 from rapidly turning  off and on if the current flow is interrupted. Additional, there is a small amount of hystersis  so that small changes in track current near the trigger point do not cause the DBD22 to turn off and on. The filter keeps the output on after a train leaves the block for a short period of time. This time is typically about 1 to 2 seconds. The amount of track current has an effect on this time.

Since the DBD22 does not use diodes to sense track current there is no drop in track voltage. This allows you to “double sense” a block. For example, suppose you want to add a grade crossing with gates and flashers to a section of track that already has a diode sensing block detector. The block could be cut into three smaller blocks to detect traffic on each approach and island blocks. DBD2s can be used for the three new blocks with out interfering with the operation of the original detector or causing an additional track voltage drop. See the SIC24 signal and indicator controller for information on implementing a grade crossing.

Specifications:

Operating voltage: 5 to 15 volts DC
Typical operating current (unoccupied): 3 mA @ 5 volts, 8 mA @ 12 volts
Typical operating current (occupied): 8 mA @ 5 volts, 20 mA @ 12 volts
Maximum load per output: 150 mA
Typical trigger current: 3 mA @ 5 volts,  6 mA @ 12 volts
Maximum sensor current: 5 A with one pass of feeder wire


Team Digital is releasing two new products in Jan 04, the Signal and Indicator Controller (SIC24) and the DCC Block Detector (DBD2). Here is a copy of the specs:

Signal and Indicator Controller (SIC24)
MSRP 54.95, Tony's $43.95

The SIC24 is uniquely suited to control various types of signals and indicators on a layout or a CTC panel. It can be used as a signal controller to indicate block occupancy and turnout position, and as a grade crossing gate controller with flashing signals. Combinations of some of these features are also possible. The SIC24 is compatible with most DCC systems.

Control signals on your layout
• Built-in logic for automatically controlling signals using block detection
• Configurable to model many signaling systems
• Control SE8C signals
• Computer not required

Control indicators on your layout or CTC panel
• Block detection
• Turnout status
• Crossing gate and flashers

Provides 24 outputs
• Drives up to eight 3 LED signal heads with common anode or common cathode
• Drives Bi-color LED searchlights with 2 or 3 leads
• Drives Tortoise™ switch machines for turnout control
• Drives Tortoise™ switch machines for semaphore signal control including the middle yellow aspect

Provides 8 inputs
• For local turnout control
• For occupancy sensors
• For turnout feedback sensors

Simple inter-board wiring
• Serial bus reduces system wiring
• Digitrax LocoNet® compatible

Simple basic setup
• Built-in setup configuration options
• "Smart Programming" in conjunction with self programming

More SIC24 info including an interactive simulation at:
http://www.teamdigital1.com/sic24%20controller.html

DCC Block Detector (DBD2)
MSRP 19.95

The DBD2 is capable of sensing current in two isolated sections of track called blocks. This provides for detecting the presence of locomotives or other rolling stock that draw current from the track.

• Two detectors with LED indicators
• Electrical isolation from the track
• No track voltage drop
• Low power requirements
• Drive relays
• Operates with SIC24 and SRC8

More DBD2 info at:
http://www.teamdigital1.com/dbd2%20sensor.html

  Phone: 800-978-3472 or 802-878-5005.
The entire site © 1997-2010 by Tony's Train Exchange. All rights reserved.
Can't find it? Try Tony's Sitemap.